Applicable Model
This information is for the following models:
- PMW-F55
Modifications from V5.11 of F55 :
1. Apple ProRes 4444 with CBK-55PD :
Apple ProRes 4444 has been added as a recording format that can be recorded/ played by installing the dedicated Option CBK-55PD. Apple ProRes 4444 can be selected when the system frequency is set to 23.98, 24.0, 25.0, or 29.97 and Main Operation is set to RGB.
2. User 3D LUT on “S-Gamut/SLog2” Color Space :
3D LUT can be now be used with“S-Gamut/SLog2” Color Space.
3. 66FPS has been added in S&Q mode :
66FPS has been added to the available Slow & Quick Motion values.
4. Improved ABB/APR action when selecting Apple ProRes and Avid DNxHD® :
Camcorder does not restart after performing ABB/APR while the recording format is set to Apple ProRes or Avid DNxHD®.
Bug Fix :
– When Interlace recording formats are selected, SDI(Main)&Internal Rec. and SDI(Sub)&HDMI was not able to be changed separately. This has been fixed.
– When MPEG50 recording format was selected, 1st and 2nd fields were inverted after executing ABB sometimes. This has been fixed.
– When SDI(Sub) output was set to “Off” and Test Out was not used, TC output was not working. This has been fixed.
– When SStP, Apple ProRes or Avid DNxHD® recording format was selected, SDI output phase was about one line delayed from Genlock signal. This has been fixed.
– Assignable Buttons setting was not loaded when ALL file generated by previous firmware version was loaded.
Please note the following :
1. iOS setting for Wi-Fi Remote :
While using Wi-Fi Remote by iOS devices and Safari, please turn off Private browse function.
2. All file Support :
All files which are created with Firmware V6.0 are not compatible with an earlier firmware version.